4000A(3P) Air Circuit Breaker



Recommended by DARUI Electric




Technical Parameters 

4000A(3P) Air Circuit Breaker Fixed Type Drawer Type Air Circuit Breaker



4000A(3P) Air Circuit Breaker (hereinafter referred to as the circuit breaker) is suitable for power distribution networks with a frequency of 50HZ, rated working voltage of 400V, 690V, and rated current from 630A to 6300A. It is used to distribute electrical energy and protect lines and power equipment from hazards such as overload, undervoltage short circuit, single-phase grounding, and other fault grounding. This circuit breaker has intelligent protection functions, precise selective protection, improves power supply reliability, and avoids unnecessary power outages. It features a compact structure, small size, and high breaking capacity. The enclosed contact system achieves zero arc flash. The intelligent controller has functions such as testing, load monitoring, large information display, on-site programming, and communication, enabling complete three-stage or four-stage protection.



Technical Parameters CDW1-3200/3P/4P/3200A Fixed Type Drawer Type Air Circuit Breaker



 



Compliance with Standards:

This product complies with GB/T14048.1-2006 "General Rules for Low-Voltage Switchgear and Controlgear" and GB14048.2-2008 "Low-Voltage Switchgear and Controlgear - Low-Voltage Circuit Breakers", and also meets the requirements of IEC60947-2 "Low-Voltage Switchgear and Controlgear - Part 2: Circuit Breakers".



Normal Working and Installation Conditions:

* Ambient air temperature: -5℃ to +40℃, with a 24-hour average not exceeding +35℃

* Atmospheric conditions: Relative humidity not exceeding 50% at an ambient temperature of +40℃; higher relative humidity is allowed at lower temperatures, e.g., 90% at 20℃. Special measures should be taken for occasional condensation due to temperature changes.

* Pollution degree: Class 3

* The circuit breaker should be installed vertically, with a vertical tilt angle not exceeding 5°

* Wiring methods: Horizontal wiring, vertical wiring




 

Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.





WeChat QR Code
💬
💬 Message

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us