Desktop|中文
Home About Us Products + News Center Technical Articles Messages Contact Us

Product Details

全自动Dielectric Loss Tester-扬州达瑞

2500A High Current Generator Price

Published: 2020-08-17 15:08:20

Views: 2922

Category: High Current Generator装置

Product Description










2500A High Current Generator Price



Recommended by Dario Electric


Main Features:



◆ High-precision sensor and high-performance 14-bit AD acquisition chip;



◆ The same output value can adjust the power level according to the size and distance of the test object; increasing the test range and increasing the safety distance from the test object.



◆ For equipment with large current value and output power, a split design is adopted; convenient for single-person carrying and operation.



◆ Optional automatic current rise test, manual current rise test, and impact quick-break test, with flexible and simple operation;



◆ Real-time display of output current, time results, intuitive and clear display;



◆ Comprehensive overcurrent protection, arbitrary setting of target output current value, current upper limit, and current withstand time;



◆ With grounding detection function and zero-return detection function, the test can only be carried out after grounding and zero-return are confirmed, safe and reliable;



◆ After power failure, it can continue output without resetting to zero and adjusting again;



◆ Approximation current rise algorithm, after reaching the set target output current, automatic current withstand timing starts, and the motor automatically returns to zero after timing ends;



◆ If the set output current upper limit is exceeded, the motor automatically returns to zero and an audible and visual alarm is issued;



◆ Combining hardware and software anti-interference technology, stable performance, strong anti-interference, suitable for harsh electromagnetic environments;



◆ Automatic error diagnosis, easy to find and solve problems;



◆ Optional remote communication, door interlock alarm light and bell, opening voltage calibration interface, etc.;



◆ Small size, light weight, reasonable structure, reliable and durable.



◆ Directly measure CT ratio and polarity.



◆ Fixed value output can measure switch action time.



◆ Multiple range selection and flexible application suitable for various test devices.



Precautions



Single equipment is heavy; when moving during testing: pay attention to personal safety. The test work must be carried out by at least two people, one operator and one supervisor, to ensure safety. Test personnel should maintain a corresponding safe distance from the test object. Test personnel should wear protective equipment and set up a warning area.

When used in low temperature, high altitude, high temperature, and high humidity environments; please read the product manual in detail; prevent equipment damage.

The shell must be grounded, do not ignore personal safety accidents due to low voltage. The instrument must be well grounded, and during use, the current rise transformer and the operation console must be reliably grounded to ensure safety.

The wire from the secondary side of the current rise device to the test object should not be too long, and the cross-section should be sufficient (current density can be considered at 6-8A/mm), and the contact surface should be cleaned (can be polished with fine gauze), otherwise the joint will heat up, and the current may not rise to the rated value.

Before work, check that the power supply has sufficient capacity, otherwise the power cord will heat up and the voltage will drop, affecting normal operation.

There should be no flammable materials at the work site. For temperature rise tests, sufficient fire extinguishing equipment should be prepared.

For continuous (temperature rise) tests, someone should be on duty at the site. And regularly check the heating condition of the current rise source equipment, wires, and joints, and make records. Due to fluctuations in the grid voltage, pay attention to adjusting the TD to maintain the rated test current. During the test, once any abnormal phenomenon is found, immediately cut off the air switch power supply, and conduct the test again after finding out the cause. After the test, the voltage regulator must be returned to zero, cut off the power supply by the air switch, cut off the working power, and remove the test wiring in the correct direction to ensure safety.

Test work should comply with the relevant provisions of the electric power safety work regulations and formulate practical safety measures.



 

Note: The above information and technical parameters are compiled and released by Yangzhou Dario Electric Co., Ltd.

 


WeChat QR Code
💬
💬 Message

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy