What are the functions of the 15KV high-voltage insulation resistance tester :
500V; 1KV; 2.5KV; 5KV; 10KV; 15KV
Function: Insulation resistance test, voltage test, current test, capacitance test Reference conditions: 23℃±5℃, below 75%rh Rated applied voltage (V): 100V; 250V; 500V; 1000V; 2500V; 5000V Accuracy: rated voltage × (1±10%) 250V; 500V; 1000V; 2500V; 5000V; 10KV Accuracy: rated voltage × (1±10%) 500V; 1000V; 2500V; 5000V; 10KV; 15KV Accuracy: rated voltage × (1±10%) Insulation resistance range (GΩ): 0.01MΩ~10TΩ Accuracy: ±3%rdg±5dgt Resolution: 0.01MΩ 0.01MΩ~35TΩ Accuracy: ±3%rdg±5dgt Resolution: 0.01MΩ 0.01MΩ~50TΩ Accuracy: ±3%rdg±5dgt Resolution: 0.01MΩ DC voltage range: 0.1~1000V Accuracy: ±1.5%rdg±3dgt Resolution: 0.1V AC voltage range: 0.1~750V Accuracy: ±1.5%rdg±3dgt Resolution: 0.1V DC current measurement: 0.01nA~6mA Accuracy: ±5.0%rdg±5dgt Resolution: 0.01nA Capacitance measurement: 10nF~50uF Accuracy: ±10%rdg±5dg (Resolution: 10nF) Output short circuit current: ≥6mA Absorption ratio and polarization index measurement: Yes Power supply: 12V rechargeable battery Backlight: Controllable gray-white screen backlight, suitable for use in dark places Display mode: 4-digit large LCD display, gray-white screen backlight LCD display size: 108mm×65mm Meter dimensions: 240mm (length)×188mm (width)×85mm (height) USB interface: With USB interface, software monitoring, stored data can be uploaded to computer, saved and printed Communication cable: USB communication cable 1 piece Test leads: High voltage probe red 3 meters, high voltage test lead black 1.5 meters, green wire 1.5 meters Data storage: 500 groups, flashing "FULL" symbol indicates storage is full Data review: Data review function: "READ" symbol display Overrange display: Overrange overflow function: "OL" symbol display Alarm function: Alarm prompt when measured value exceeds alarm set value Power consumption: Standby: 30mA Max (backlight off) Power on with backlight: 42mA Max Measurement: 200mA Max (backlight off) Meter weight: 2340g (including battery) Battery voltage: Low battery symbol displayed when battery voltage is insufficient Auto power off: Meter powers off after about 15 minutes of no operation Insulation resistance: ≥50MΩ (between measuring circuit and housing) Withstand voltage: AC3kV/50Hz 1min Operating temperature and humidity: -10℃~+50℃<85%RH Storage temperature and humidity: -15℃~+55℃<90%RH Applicable safety standards: IEC61010-1, IEC1010-2-31, IEC61557-1,5, IEC60529(IP54), pollution degree 2, CAT Ⅲ 300V
Hello! How can I help you?