Power Plant Heating Cable Overview ● Stainless Steel Power Plant Heating Cable
The stainless steel sheathed series heating cables can meet the requirements of high temperature conditions and high heating power (up to 300W/m). The maximum withstand temperature of power plant heating cables can reach 800°C, with conductor resistance ranging from 28000 to 19.2Ω/km. Power plant heating cables have excellent mechanical strength and corrosion resistance.
● Copper Sheathed Power Plant Heating Cable
The copper sheathed series heating cables can meet the requirements of high temperature conditions and long-distance pipeline heat tracing. The maximum withstand temperature of copper sheathed power plant heating cables can reach 250°C, with conductor resistance ranging from 480 to 0.5Ω/km. For applications requiring corrosion protection or buried installation, power plant heating cables have excellent mechanical strength.
● 825 Alloy Sheathed Power Plant Heating Cable
The copper-nickel alloy sheathed power plant heating cables can meet the requirements of high temperature conditions and long-distance pipeline heat tracing. The maximum withstand temperature of copper-nickel alloy sheathed power plant heating cables can reach 400°C, with conductor resistance ranging from 28000 to 19.4Ω/km. Power plant heating cables have excellent mechanical strength and corrosion resistance.
[Power Plant Heating Cable Introduction]
II. Technical Parameters: Sheath Material: 1. USU304 2. USU321 3. 310S 4. 825 Alloy and other stainless steels
Insulation Material: High-purity mineral magnesium oxide
Heating Core Wire: 1. Nickel-chromium alloy 2. Copper-nickel alloy 3. PTC constant temperature alloy
Number of Cores: 1. Single core 2. Dual core Cold End Length: 500MM (non-heating)
Cold End Gland: 1. NPT1/2 2. NPT3/4 3. 16X40 (specify for special requirements when ordering)
III. Power Plant Heating Cable Applications Power plant heating cables are widely used in chemical pipelines (such as benzene, styrene, propylene glycol, benzaldehyde), crude oil pipelines, wax, asphalt, heavy oil, residue oil, coking, distillation pipelines, reactor preheating, LNG pipelines and storage tanks, CNG pipelines and storage tanks, plateau railway tunnel drainage anti-icing, power plant steam turbine guide pipes, sulfuric acid pickling heating pipes, acidic gas environment pipelines, metallurgy, pharmaceuticals, and various other industries.
IV. Power Plant Heating Cable Standards Power plant
heating cables with maximum temperature below 250°C comply with IEC800 (92) standard, "Heating cables for household facilities heating and anti-icing with rated voltage 300/500V". Power plant heating cables exceeding 252°C comply with enterprise standards.