Product Description
Transformer Characteristic Comprehensive Test Bench Price



Dare Electric recommends for you




Main Functions:


Used to test the DC resistance of switch contacts, circuit breaker contacts, busbars, contacts, SF6 switches, various connections, fuses, and railway connections. Working principle: The M400 uses a thyristor rectifier circuit to adjust the test current to a preset value. This current, after rectification and filtering, is applied to the sample under test, and the resistance value is directly measured. In this current, the voltage is applied to the unknown circuit under test and compared with a circuit of known resistance, and the reading is displayed on a digital ammeter. The test principle adopts a four-terminal test method. The four-terminal connection method is used for the unknown resistance under test and its parallel circuit. The test circuit and its selection switch determine the test range.




Technical Specifications:


1. Output current: 5A, 10A


2. Measurement range: 5A: 1mΩ~4Ω 10A: 1mΩ~1Ω


3. Resolution: 1μΩ


4. Test accuracy: 0.2 class


5. Operating temperature: -10℃~50℃


6. Operating humidity: 0~80%


7. Power supply: AC 220V±10% 50Hz±1Hz




Main Technical Indicators:


>Measurement range: 0~2000Ω. (Six ranges in total)


Test current: 5A (20mΩ~2Ω); 0.5A (20Ω); 0.05A (200Ω); 0.005A (2000Ω).


>Resolution: 1μΩ (20mΩ range); 10μΩ (200mΩ range); 0.1mΩ (2Ω range); 1mΩ (20Ω range); 10mΩ (200Ω range); 0.1Ω (2000Ω range). >Accuracy: 1mΩ~2000Ω (±0.5%)


>Power consumption: ≤100W


>Operating temperature and humidity: 0℃~40℃; ≤85% RH


>Withstand voltage: AC 1.5kV 50Hz 1min


>Power supply: AC220V 50Hz (±10%)


>Dimensions: 350mm(L)×260mm(W)×140mm(D)


>Weight: approx. 30kg




Safety Measures:


1. Before using this instrument, you must carefully read this manual.


2. The operator of the instrument should have general electrical knowledge.


3. Avoid using the instrument in places with rain, corrosive gases, excessive dust, high temperature, direct sunlight, etc.


4. The instrument should avoid severe vibration.


5. After testing, be sure to wait until the discharge alarm sound stops before turning off the power and removing the test leads.


6. When measuring no-load tap-changing transformers, be sure to wait until the discharge indicator alarm sound stops before switching gears.


7. During the test, it is forbidden to move the test clips and the power supply lines.




Precautions:


1. For no-load tap-changing windings, it is not allowed to switch the no-load tap changer during the test or before the discharge is complete.


2. For inductive test objects, it is not allowed to remove the test leads before the discharge is complete (when the buzzer is sounding), to avoid electric shock.


3. If the external AC220V suddenly loses power during the test, the instrument will start automatic discharge. At this time, it is not allowed to remove the test leads immediately; only after 5 minutes can the leads be removed.



Note: The above information and technical parameters are compiled and released by Yangzhou Dare Electric Co., Ltd.





WeChat QR Code
💬
💬 Message

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us