TAG-8800 Remote Wireless High-Voltage Phase Detector Overview
Relevant Standards:
1. The main advantage is that it eliminates the leads connecting the two power grids (power sources), with a distance of up to 20m, and can pass through walls and partitions (panels), unrestricted by any terrain or facility structure, improving safety.
2. Operation is convenient, requiring only one operator and one supervisor.
3. During operation, the instrument sends digital signals to the receiving end via a wireless transmission module, thereby reducing interference, minimizing errors, and greatly improving the instrument's performance.
4. In use, first operate the receiving device on the conductive part of the tested power grid, then operate the receiving device on the conductive part of the other tested power grid. If the phases of the two tested power grids are the same, a voice prompt repeats: "Phase same"; if the phases are different, a voice prompt repeats: "Caution, phase different".
5. The insulating operating tube (material) uses the Sanqiu brand moisture-proof insulating tube produced by a military enterprise, complying with the EC/1C78 standard, featuring moisture resistance, high voltage resistance, impact resistance, and bending resistance.
TAG-8800 Remote Wireless High-Voltage Phase Detector Technical Parameters:
1. Application Range: 6~35kV, 110KV, 220KV, 500KV and other voltage levels
2. Test Object Status: Live parts of lines or equipment
3. Height Above Ground: Less than 15 meters
4. Maximum Distance Between Transmitters: Less than 30 meters
5. Equipment Operating Frequency: 1.2GHZ
After-Sales Service System:
1. Our company has a professional after-sales service team, headed by the vice president in charge of sales.
2. The after-sales service department currently has 10 staff members, ensuring timely maintenance of our products.
3. Our after-sales service goal is to promptly resolve on-site equipment failures with rapid response,
Precautions and Maintenance:
1. When performing frequency transmission calibration, ensure the antenna is installed before calibration. The housing of the high-voltage phase detector is made of polycarbonate and must be kept clean; any dirt or moisture must be wiped off. After each use, wipe the instrument with a cloth dipped in a little silicone oil.
2. When not in use, the instrument must be properly stored in its case.
3. In low-temperature environments (-10 degrees or lower), the instrument must be stored in a warm place as batteries may fail when cold.
4. The instrument should be tested before each use.
The line-of-sight transmission distance between the main unit and the X and Y collectors is: X≥80m, Y≥50m
Working Environment: -35℃~+50℃ Humidity: ≤95%RH
Storage Environment: -40℃~+55℃ Humidity: ≤95%RH
Insulating Telescopic Pull Rod: Retracted state 600mm, Extended state 3200mm
Packaging Box Dimensions (Length×Width×Height): 650mm×250mm×100mm
Total Product Weight: 5kg