Introduction:
The fully automatic high current generator is essential equipment for places requiring high current during debugging in the power and electrical industry. This device has the characteristics of easy maintenance, superior performance, safe and reliable use, beautiful appearance, sturdy and durable, and easy to move. It is necessary equipment for power supply enterprises, large factories, metallurgy, power plants, railways, and other departments requiring power maintenance. It adopts advanced microelectronic processing technology, and the entire use process can be set in advance. The all-Chinese interface makes operation simple and clear. After setting all test items, the test is automatically performed without manual intervention.
Features:
A. Light weight, strong load capacity!
B. Output current: three-phase absolutely balanced, waveform is standard sine wave
C. Three-phase simultaneous adjustment, or each phase can be adjusted separately
Note: Three-phase high current generator (current can be increased according to user requirements).
Functional features: (1) Imported iron core, small size and light weight (2) 0.5-class digital true RMS meter
(3) No need for external standard CT and ammeter
(4) Coarse and fine adjustment, zero position indication, power supply 220/380/66V
The high current generator adopts an energy-saving high-permeability current booster, and the instrument is indicated by a true RMS 0.5-class digital meter. It is also equipped with a digital electric stopwatch to meet time measurement. It has the characteristics of large output power, strong overload capacity, clear reading, and flexible movement. It is suitable for power system technicians to test current transformers, protection devices, and secondary circuit current tests.
Input power: AC 220V 50Hz.
Rated output: 0-1500A, 2000A, 3000A, 4000A, 5000A, 8000A, 10000A.
Output terminal open-circuit voltage ≥6V.
Dimensions: 540X300X250 (mm)
Parameters:
◆ Input voltage: AC220V/380V±10% 50Hz±1
◆ Output current: 0-20kA (customizable according to customer requirements)
◆ Output capacity: 0-10kVA
◆ Current withstand timing range: 0-9999S
◆ Surge timing range: 0-999mS
◆ Ambient temperature: -20℃ to 50℃
◆ Current accuracy: ≤0.5% (F.S)