Product Introduction

    The TPJYX-B Insulation Boots (Gloves) Withstand Voltage Test Device is based on the principle of electromagnetic induction, changing the input voltage to reach the maximum voltage required for the test.

    The TPJYX-B Insulation Boots (Gloves) Withstand Voltage Test Device consists of two parts: a water tank and a control console. The water tank is divided into upper and lower sections. The upper section has 6 small water tanks, and the lower section houses the test transformer, allowing for withstand voltage tests on 6 insulation boots or 6 insulation gloves at a time. It simultaneously displays the leakage current of the insulation boots or gloves. The control console is equipped with overcurrent protection, zero-position protection, time protection, and alarm functions.



Environmental Conditions

   1. Ambient temperature: 0~40℃

   2. Relative humidity: ﹤85% (when air temperature is 25℃)

   3. Altitude: ﹤1000m

   4. Input power supply harmonic content: ﹤3%

  

Technical Parameters

   1. Working power supply: AC220V±10%  50Hz

   2. Input voltage: 220V

   3. Input current: 15A

   4. Capacity: 3KVA

   5. Output voltage: 0~25KV

   6. Output current: 120mA