DLKG High and Low Voltage Switchgear Power-on Test Bench







Product Detailed Introduction


The DLKG high and low voltage switchgear power-on test bench is used by high and low voltage switchgear manufacturers to conduct various power-on tests before delivery. It can provide various AC and DC power supplies, facilitating the testing of switchgear and improving work efficiency.



High and low voltage switchgear test bench, switchgear power-on test bench, switchgear test, switchgear type test bench, high voltage switchgear test bench, low voltage switchgear test bench



1. Provide various AC and DC power supplies;

2. Convenient for testing switchgear;

3. Helpful to improve work efficiency.



Operating environment:

  Temperature: -10~45℃   Humidity: ≤85% 

  Altitude: ≤1000m

  The place of use should be free of gases that seriously affect insulation, chemical dust, and other explosive and corrosive media.

  There should be a good grounding device.



Model Input Power Supply Output Power Supply Dimensions (mm) Weight (kg) 

DLKG

Basic Type 

Three-phase four-wire

AC 380V 50Hz

(Terminal form)



 1. Single-phase AC 220V output (fixed value, socket or two-hole terminal form)      Two groups

2. Three-phase AC 380V output (fixed value, socket or three-hole terminal form)      One group

3. Three-phase AC 100V output (fixed value, three-hole terminal form)            One group

4. AC operating voltage output AC 0~400V (three-hole terminal form)         One group

5. AC current output three-phase AC 0~10A  (three-hole terminal form)         One group

6. DC operating voltage output DC 0~260V (three-hole terminal form)         One group 650×750×800 45 

DLKG-II

DC multi-gear output Same as above Parameters same as basic type

Add item 7: 

7. DC fixed multi-gear output DC 24V 36V 110V  220V         One group 650×750×800 50 

DLKG-III

Capacitor cabinet switching test Same as above 

Parameters same as basic type

Item 4 increases capacity current: 

4. AC operating voltage output AC 0~400V, at 220V ≥30A         One group 650×750×800 60 

DLKG-IV

DC closing power supply Same as above 

Parameters same as basic type

Add item 7:

7. DC closing DLKG-300A power supply (6-hole thyristor adjustment) output DC 0~300V

(Rated current 100A, short-time working current 300A)                   One group   650×750×800 70 

DLKG-V Ultimate Edition

Withstand voltage function Same as above 

In addition to the functions of DLKG basic type, type II, and type IV 

9. Integrated 0~5kV high voltage output function including overcurrent protection, timing function and other control units 650×750×800 90 

DLKG-X Customized Version Same as above 

A. DC fixed multi-gear output DC 24V 36V 110V  220V

B. DC closing DLKG-300A power supply (6-hole thyristor adjustment) output DC 0~300V

(Rated current 100A, short-time working current 300A)

C. AC withstand voltage 0~3kV/0~5kV withstand voltage 1-99 time automatic instantaneous boost (DL-5KV 3C withstand voltage tester | power frequency withstand voltage detector | electrical appliance withstand voltage tester)

D. Ground resistance measurement: 4~30A current 6V voltage 1~500mΩ range 1~99s time (DL-10A 3C ground resistance tester)

E. Range phase voltage, line voltage detection Uan Ubn Ucn Uab Ubc Uca off 7 gears