Automatic Insulating Boots (Gloves) Withstand Voltage Test Device HZJY-105
I. Product Overview:
HZJY-105 Automatic Insulating Gloves Withstand Voltage Test Device is a dedicated equipment for batch testing of insulating boots (gloves). It effectively solves the previous irregular testing methods, simplifies the testing procedure, improves testing speed, reduces testing intensity, ensures the safety of testing personnel, and reliably identifies parameters such as leakage current, insulation aging, and power frequency withstand voltage of insulating gloves (boots). It can test six insulating gloves (boots) simultaneously. The device integrates the high-voltage power supply and control system into one unit, featuring simple wiring and operation, reasonable and reliable layout, easy mobility, and flexible assembly/disassembly. It is an ideal replacement product. Executive Standards: GB17622-1998, DL/T976-2005
Product Aliases: Protective Tool Insulation Test Bench, Insulating Boots and Gloves Withstand Voltage Test Device, Insulating Boots and Gloves Withstand Voltage Tester, Auxiliary Insulation Tool Test Device, Insulating Boots and Gloves Test Device, Live Working Protective Equipment Insulation Test Device, Insulating Shoes and Gloves Testing Machine, Insulating Boots and Gloves Testing Machine.
II. Product Features:
1. 320×240 LCD display, high-speed thermal printer.
2. Measures high voltage, low voltage current, and 6 leakage currents (8 channels in total), using high-precision sensors and high-performance 14-bit AD acquisition chips.
3. Human-machine dialogue with full keyboard operation, intelligent throughout the entire process, with selectable automatic and manual withstand voltage modes.
4. Real-time display of high voltage, low voltage current, 6 leakage currents, time, and withstand test results, with clear and intuitive display.
5. Automatically saves setting data; after power-off, the last settings are displayed upon startup.
6. Comprehensive overvoltage and overcurrent protection, with arbitrary setting of output voltage, low voltage current upper limit, leakage current upper limit, and timing duration.
7. Equipped with zero-return detection function; the test can only be performed after confirming zero return, ensuring safety and reliability.
8. Approach-type voltage regulation algorithm; after reaching the set voltage, automatic withstand voltage timing begins, and after timing ends, voltage automatically decreases to zero.
9. If the set low voltage current upper limit or leakage current upper limit is exceeded, the voltage output is automatically cut off, voltage decreases to zero, and an audible and visual alarm is triggered.
10. Excellent software and hardware anti-interference design, with multiple anti-interference measures to adapt to harsh electromagnetic environments.
11. Automatic error diagnosis, making it easy to identify and solve problems.
12. Optional remote communication, door interlock alarm light and bell, external voltage divider calibration interface, etc.
Product Parameters
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|