SRY2-/SRY4- Series Immersion Oil Heaters Specifications and Technical Parameters:

2. Operating voltage tolerance: not greater than 1.1 times its rated value. The shell must be effectively grounded.

3. Operating environment: relative humidity not greater than 95%, free from explosive, flammable, and corrosive gases.

4. Metal tube material: No. 10 steel.

5. Maximum operating temperature: 100°C.

6. Working pressure for SRY2 and SRY4 types: less than 0.6MPa.

7. Oil tank opening: φ65.

III. Usage, Maintenance, and Precautions:

1. Dimension "B" in the outline drawing must be fully immersed in oil to avoid burning the components. The heated oil should be non-corrosive.